Related Experiment Video
Updated: Aug 6, 2026

Investigating the Potential of Singly Curved Thin Piezoelectric Transducers for Energy Harvesting and Structural Health Monitoring
Published on: November 14, 2025
Nonlinear processing of the output voltage of a piezoelectric transformer
Daniel Guyomar1, Christophe Magnet, Elie Lefeuvre
1Laboratoire de Gène Electrique et de Férroélectricité (LGEF), INSA de Lyon, Bâtiment Gustave Ferrié, 69621 Villeurbanne, France
Abstract:
Reducing the size of power supplies raises the problem of new components that could be better candidates for integration. In this field, electromagnetic transformers may be replaced with significant benefit by piezoelectric transformers (PT). In a PT, the input electrical energy is transferred to the output by an acoustical means, using the direct and converse effects of piezoelectric materials. Its main advantages over an electromagnetic transformer are no magnetic noise generation, small size, high power density, and high efficiency. This paper deals with an innovative technique that produces a significant improvement of the power capability of piezoelectric transformers. This technique is based on a particular output voltage processing of the PT. Its effect is a vibration level reduction of the PT structure while keeping the output power practically constant. Vibration level is a critical parameter that determines the maximum power capability of a given PT. Thus, the new processing reduces significantly the losses of the PT. Both theoretical predictions and experimental results show that the increase of the power capability may reach 200%.
Related Concept Videos
Bridge rectifier
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
Transformers with Off-Nominal Turns Ratios
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
MOSFET Amplifiers
Full wave rectifier