Forearm cephalic vein cross-sectional area changes at incremental congestion pressures: towards a standardized and
R Nils Planken1, Xavier H Keuter, Alfons G Kessels
1Department of Vascular Surgery, Maastricht University, Maastricht, The Netherlands. N.Planken@surgery.azm.nl
Objectives:
Duplex ultrasonography assessment of superficial forearm veins is frequently used before a hemodialysis arteriovenous fistula (AVF) is created. There is, however, no standardized preoperative duplex ultrasonography protocol. This study assessed B-mode image analysis reproducibility and reproducibility of repeated forearm superficial venous diameter measurements on different days at different venous congestion pressures (VCPs).
Methods:
Diameters were determined using B-mode ultrasonography in 10 healthy male volunteers on days 1 and 14 at incremental VCP values (10 to 80 mm Hg). Intra- and interobserver agreement was assessed for B-mode image analysis by calculating interclass correlation coefficients (ICC). Reproducibility of repeated diameter measurements (maximum and minimum diameter at days 1 and 14), cross-sectional area size increase, and shape change due to incremental VCPs were determined by calculating ICC values.
Results:
Analysis of intraobserver agreement of B-mode image interpretation yielded ICC values of 0.97 (95% confidence interval [CI], 0.94 to 0.99) and 0.97 (95% CI, 0.96 to 0.99) for determination of maximum and minimum diameters, respectively. Interobserver agreement analysis yielded ICC values of 0.95 (95% CI, 0.92 to 0.97) and 0.96 (95% CI, 0.96 to 0.99) for determination of maximum and minimum diameters, respectively. Reproducibility of repeated diameter measurements on days 1 and 14 improved substantially at incremental VCP values, with best reproducibility at VCPs >40 mm Hg. Repeated determination of cross-sectional area size increase and shape change due to VCP increase from 10 to 80 mm Hg yielded ICC values of 0.49 (95% CI, 0.19 to 1.00) and 0.09 (95% CI, 0.00 to 0.92), respectively. Maximum and minimum diameters as well as cross-sectional area size increased significantly (P < .01) due to VCP increase during both sessions. Cross-sectional area shape changed significantly (P < .01) due to VCP increase during both sessions.
Conclusions:
Diameter measurements on B-mode images are largely observer independent. Superficial venous cross-sectional area shape is noncircular, and cross-sectional area size depends on VCP. Both maximum and minimum venous diameters should be determined at VCPs >40 mm Hg to attain the best reproducibility. Further studies are needed to determine whether a standardized preoperative vein mapping protocol can reduce AVF nonmaturation rates.
Related Concept Videos
Veins of Upper Limbs
The deep venous system is primarily composed of the ulnar and radial veins. The ulnar vein, which drains the fingers through the superficial palmar venous arches, and the radial vein, which serves the palms via the deep palmar...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...