Blood attenuation with SSFP-compatible saturation (BASS).

Hung-Yu Lin1, Brian M Dale, Chris A Flask

  • 1Department of Radiology, University Hospitals of Cleveland and Case Western Reserve University, Cleveland, OH 44106, USA.

Journal of Magnetic Resonance Imaging : JMRI
|August 8, 2006
PubMed
Summary

Researchers developed a new MRI technique that darkens blood flow in images to better see vessel walls. This method modifies standard rapid imaging to improve clarity without sacrificing speed. Tests in animals show it effectively reverses blood brightness compared to traditional scans.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

VEGFC as a prognostic cytokine biomarker linking lymph node metastasis to immune suppression in breast cancer.

European cytokine network·2026
Same author

Multiplex biomarker detection platform based on zinc protoporphyrin-modified gold electrodes: Application potential for early diagnosis and postoperative monitoring of prostate cancer.

Biosensors & bioelectronics·2026
Same author

A pilot study of magnetic resonance fingerprinting and radiomics analysis in autosomal dominant polycystic kidney disease.

Kidney international·2026
Same author

A Comparison of the Tofts and Linear Reference Region Models for DCE MRI When Monitoring Vascular Disruption in a Preclinical Tumor Model.

NMR in biomedicine·2026
Same author

A culturally adapted online Mediterranean diet intervention for metabolic dysfunction-associated steatotic liver disease (TIMA): study protocol for a randomized controlled trial.

Trials·2026
Same author

Caffeinated chewing gum improves military performances in special forces soldiers.

European journal of applied physiology·2026

Area of Science:

  • Cardiovascular imaging outcomes research within BASS medical physics
  • Diagnostic radiology and medical imaging technology

Background:

Current magnetic resonance imaging techniques often struggle to distinguish vessel walls from the surrounding blood pool. This limitation hinders the precise assessment of vascular structures in clinical settings. Prior research has shown that bright blood signals frequently obscure fine details of the vessel anatomy. That uncertainty drove the development of specialized sequences to suppress moving spin signals. No prior work had resolved the trade-off between rapid acquisition speeds and high-quality dark-blood contrast. This gap motivated the creation of novel pulse sequences for improved cardiovascular visualization. Existing methods often required long scan times or complex hardware configurations to achieve sufficient suppression. Researchers sought to overcome these hurdles by refining standard imaging protocols for better diagnostic utility.

Purpose Of The Study:

The investigators aimed to develop a rapid flow-suppression method for improving the contrast-to-noise ratio in cardiovascular applications. This study addresses the challenge of distinguishing vessel walls from the blood lumen during imaging. Researchers sought to enhance image clarity without compromising the speed of standard steady-state free precession techniques. The motivation stems from the need for better visualization of vascular anatomy in clinical diagnostics. No prior work had successfully balanced these competing requirements for rapid, high-contrast imaging. The team focused on modifying existing pulse sequences to achieve dark-blood effects. By suppressing moving spins, they intended to provide a clearer view of the vessel structure. This effort aims to refine current imaging protocols for more accurate assessment of cardiovascular health.

Keywords:
MRI pulse sequencesteady-state free precessionvessel wall imagingcontrast-to-noise ratio

Frequently Asked Questions

The researchers propose that moving spins are attenuated because they fail to undergo full refocusing at the echo time. This mechanism effectively reduces the signal amplitude from blood flow, contrasting with the static spins that remain bright in the slice.

The sequence utilizes a pair of excitation pulses per repetition time. The first pulse targets the region adjacent to the slice, while the second pulse is a slice-selective excitation pulse designed to generate the steady-state free precession signal.

The slice-selective pulse is necessary to isolate static spins within the region of interest. Without this specific pulse, the sequence would fail to generate the required steady-state signal, preventing the differentiation between static tissue and moving blood.

The authors employ both computer simulations and animal imaging trials to validate the sequence. These data types allow for the comparison of theoretical signal behavior against actual performance in a biological environment.

Related Experiment Videos

Main Methods:

The investigators designed a novel dark-blood sequence by modifying the standard steady-state free precession framework. Their approach involves applying two distinct excitation pulses during each repetition time interval. One pulse targets the area immediately neighboring the slice, while the other acts as a slice-selective pulse. Following this excitation, the team implemented fully refocused gradients across all three imaging axes. The researchers utilized computer modeling to predict signal behavior before conducting physical trials. Animal subjects underwent imaging to verify the performance of the proposed sequence in vivo. The team calculated the total acquisition time increase to assess the efficiency of the new protocol. This systematic review approach ensured that both theoretical predictions and practical outcomes were thoroughly evaluated.

Main Results:

The new sequence successfully reversed the lumen-to-muscle contrast-to-noise ratio from 14.77 to -13.96. This shift confirms the effective suppression of blood signals compared to traditional bright-blood imaging methods. The authors observed that the technique requires a 24.2% increase in acquisition time relative to standard steady-state free precession. Despite this increase, the method preserves the rapid imaging capabilities of the original sequence. Simulations provided clear evidence that moving spins experience significant signal attenuation at the echo time. Animal trials corroborated these findings by demonstrating high-quality dark-blood contrast in the vessels. The results indicate that the modification effectively limits unwanted bright signals within the lumen. These findings represent a substantial improvement in the contrast between vessel walls and blood flow.

Conclusions:

The authors propose that their modified sequence successfully achieves dark-blood contrast while maintaining rapid imaging performance. This approach reverses the lumen-to-muscle contrast-to-noise ratio compared to standard bright-blood acquisitions. The study confirms that the technique effectively limits unwanted signal from moving spins within the vessel lumen. These findings suggest that the method preserves the speed advantages inherent to steady-state free precession imaging. The authors note that the implementation requires only a modest increase in total acquisition time. This development provides a viable alternative for clinicians needing clear vessel wall visualization. The results demonstrate that simple adaptations to existing pulse structures can yield significant improvements in image quality. Future clinical applications may benefit from the enhanced contrast provided by this specific sequence design.

The researchers measured the lumen-to-muscle contrast-to-noise ratio to evaluate performance. The value shifted from 14.77 in standard bright-blood scans to -13.96 when using the new dark-blood sequence.

The authors suggest that this method allows for improved vessel wall visualization. They propose that this approach maintains the rapid imaging benefits of steady-state free precession while overcoming the limitations of bright-blood signal interference.