Related Experiment Video
Updated: Aug 6, 2026

Assessment of Respiratory Function in Conscious Mice by Double-chamber Plethysmography
Published on: July 10, 2018
Bench evaluation of flow limitation detection by automated continuous positive airway pressure devices
Frédéric Lofaso1, Gilbert Desmarais, Karl Leroux
1National Institute for Health and Medical Research (Institut National de la Santé et de la Recherche Médicale), Unit 651, Henri Mondor Teaching Hospital, Créteil, France. f.lofaso@rpc.ap-hop-paris.fr
Study Objective:
Automatic continuous positive airway pressure (CPAP) devices that adjust the pressure delivered to the patient are now available to treat sleep-disordered breathing. Sophisticated auto-CPAP devices can detect and correct flattened inspiratory flow contours (FIFCs) associated with subtle upper airway obstruction. However, evaluations of their performance are made difficult by differences across patients and devices. We performed a bench study of five commercially available auto-CPAP devices using a breath waveform simulator to evaluate sensitivity for detecting flattened inspiratory flow.
Design:
Five degrees of FIFC were simulated. In addition, normal and abnormal flow contours from patients published in the literature were evaluated.
Measurements And Results:
One device showed autotriggering leading to CPAP increases, and another device varied the CPAP level independently from the presence of an FIFC. The three remaining devices differed regarding the detection of FIFCs and the means used to increase CPAP.
Conclusion:
Based on the characteristics of each patient, physicians must choose among devices with different thresholds of FIFC detection and different pressure responses to detection. Therefore, physicians need details on the algorithms used in auto-CPAP devices. Manufacturers should supply detailed algorithms.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...

