Color Doppler ultrasonography as a routine clinical examination in male infertility
Hideo Sakamoto1, Katsuyuki Saito, Takeshi Shichizyo
1Department of Urology, Showa University Fujigaoka Hospital, Showa University School of Medicine, Kanagawa, Japan. hs-showa-u@med.showa-u.ac.jp
Aim:
We assessed the value of scrotal color Doppler ultrasonography as a routine examination in infertile men.
Methods:
Color Doppler ultrasonography was performed in 545 infertile men with a mean age of 35.8 years to detect intrascrotal abnormalities. Findings were compared with those of physical examination.
Results:
Intrascrotal abnormalities were detected by ultrasonography in 65.3% of patients. Of 374 abnormalities, 58.3% were undetected by physical examination. Left varicocele was found in 313 patients (57.4%); testicular microlithiasis in 30 (5.5%); epididymal cyst in 21 (3.9%); right varicocele in 4 (0.8%); and testicular cysts in 3 (0.6%). One occurrence each (0.2%) was found for testicular tumor, intrascrotal hemangioma, and hydrocele of the spermatic cord. Compared to ultrasonography, sensitivity in detecting left varicocele by physical examination was 58.4%; specificity, 79.3%; accuracy, 67.3%; and positive predictive value, 79.3%. Venous diameters in the pampiniform plexus were 3 mm or more in 61.5% of 130 subclinical left varicoceles. Of 30 patients with testicular microlithiasis, 14 had varicocele, 2 had epididymal cyst,s 3 had a history of mumps orchitis, 1 had retractile testis, and 1 had a history of orchiectomy for contralateral testicular tumor.
Conclusions:
The routine Color Doppler ultrasonography is valuable for diagnosing scrotal abnormalities in infertile men, frequently detecting non-palpable lesions.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies II: Ultrasonography
Infertility in Males
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...