Objective:
To evaluate the effect of positive end-expiratory pressure (PEEP) on oxygen delivery (DO(2)) with 1-lung ventilation during thoracoscopy in normal anesthetized dogs.
Study Design:
Prospective, controlled experimental study.
Animals:
Eight, adult, intact Walker Hound dogs weighing 25.6-29.2 kg.
Methods:
Anesthetized dogs had 1-lung ventilation during an open-chest condition. A Swan-Ganz catheter was used to measure pulmonary hemodynamic variables and to obtain mixed venous blood samples for blood gas analysis. A dorsal pedal catheter was used for measurement of systemic arterial pressure and to obtain arterial blood samples for blood gas analysis. Oxygen delivery was calculated and used to assess the effect of 0, 2.5, and 5 cm H(2)O PEEP during 1-lung ventilation on cardiopulmonary function. Each dog was its own control at 0 cm H(2)O PEEP. A randomized block ANOVA for repeated measures was used to evaluate the effect of the treatment on hemodynamic and pulmonary variables.
Results:
Use of 5 cm H(2)O PEEP induced a significant augmentation in the arterial partial pressure of oxygen (PaO(2)). Shunt fraction (Q(s)/Q(t)), physiologic dead space (V(D)/V(T)), and the alveolar-arterial oxygen difference (P(A-a)O(2)) decreased significantly after 5 cm H(2)O PEEP, compared with 1-lung ventilation without PEEP. Use of 2.5 cm H(2)O PEEP had no significant effect on cardiopulmonary variables. Use of PEEP had no significant effect on arterial oxygen saturation (SaO(2)), DO(2), and hemodynamic variables in normal dogs.
Conclusions:
PEEP had no effect on DO(2) in normal dogs undergoing open-chest 1-lung ventilation because it had no adverse effect on hemodynamic variables.
Clinical Relevance:
PEEP in normal dogs during open-chest 1-lung ventilation for thoracoscopy is not detrimental to cardiac output and can be recommended in clinical patients.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...