Comparative evaluation of three high-performance liquid chromatography-based Kow estimation methods for highly
Stephen J Hayward1, Ying D Lei, Frank Wania
1Department of Chemical Engineering and Applied Chemistry and of Physical and Environmental Sciences, University of Toronto at Scarborough, 1265 Military Trail, Toronto, Ontario M1C 1A4, Canada.
Abstract:
Three methods for estimating the octanol-water partition coefficient (Kow) based on its relationship with capacity factors on reversed-phase (RP) high-performance liquid chromatography (HPLC) columns were compared in terms of their applicability to highly hydrophobic compounds (HHCs). Methods based on simple isocratic elutions were found to be unsuitable, because the very high organic modifier fractions that are required to elute HHCs from RP columns challenge the basic assumption of the similarity between the octanol-water and RP-eluent systems. Compound planarity was found to exert a considerable influence on the retention of HHCs in RP columns, leading to different linear calibration curves for chlorobenzenes and chlorobiphenyls. Only an empirical exponential regression succeeded in describing the behavior of both groups of compounds during gradient elutions. In a method based on isocratic retention times at multiple temperatures, satisfactory calibration was achieved with a multivariate linear regression that included a numerical indicator of compound planarity. Considering experimental simplicity, speed, precision, and accuracy, with the latter judged by comparison with Kow values for polybrominated diphenyl ethers and polychlorinated naphthalenes as reported in the literature, a gradient elution combined with an exponential calibration curve is recommended for estimating the Kow of HHCs. To our knowledge, the first isomer-specific Kow values for hexabromocyclododecane are reported. Bearing in mind that the influence of structural characteristics on retention is likely to increase with hydrophobicity, it is not justified to judge a HPLC-based Kow estimation method as being suitable for HHCs because it is shown to work well for less hydrophobic substances. Whereas univariate linear regressions often may prove to be sufficient when dealing with substances having a log Kow, of less than five, methods for HHCs need to account for the influence of structure on retention.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Organic Compounds
Ethers from Alcohols: Alcohol Dehydration and Williamson Ether Synthesis
Ethers can be prepared from organic compounds by various methods. Some of them are discussed below,
Preparation of Ethers by Alcohol Dehydration
In this method, in the presence of protic acids, alcohol dehydrates to produce alkenes and ethers under different conditions. For example, in the presence of sulphuric acid, dehydration of ethanol at 413 K yields ethoxyethane, whereas it yields ethene at 443 K.