Related Experiment Video
Updated: Aug 6, 2026

Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Work of breathing in anesthetized infants increases when a breathing system filter is used
Graham T Bell1, Kerryn M Martin, Stephen Beaton
1Department of Anaesthetics, Royal Hospital for Sick Children, Dalnair St, Glasgow G3 8SJ, UK. graham.bell@yorkhill.scot.nhs.uk
Background:
There are concerns that the inclusion of a pediatric heat and moisture exchange filter (HMEF) is in a breathing system may cause an unacceptable increase in the work of breathing. This study is the first study to objectively measure the increase in work of breathing in the infant population when an HMEF is added to the pediatric breathing circuit.
Methods:
Ten patients weighing 3-8 kg were studied in a randomized crossover trial. Work of breathing was analyzed using the integral of pressure-volume loops.
Results:
The median increase in the work of breathing associated with the addition of an HMEF was 279 mJ x min(-1) (95% CI, 165-903 mJ x min(-1)). This equates with a percentage increase of 43% (95% CI, 25-138%).
Conclusions:
Because of the substantial increase in the work of breathing with an HMEF attached to the tracheal tube, consideration should be given to alternative means of humidification and filtration during periods of spontaneous ventilation in small infants.
Related Concept Videos
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Mechanism of Breathing I: Inspiration
The respiratory system, an essential network for breathing, comprises the conducting and respiratory zones, each playing a crucial role in the overall process of respiration. Let us explore the detailed mechanism of inspiration, or inhalation, which is the first phase of the respiratory cycle.
Pathway of Air during Inspiration
During inspiration, air enters our body through the nose or mouth and moves through the conducting zone,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Other Factors Affecting Respiration Centers
However, the ability to hold one's breath voluntarily is not limitless. When the CO2 concentration in the blood reaches a critical level,...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...