Related Experiment Video
Updated: Aug 4, 2026

Development of Sulfidogenic Sludge from Marine Sediments and Trichloroethylene Reduction in an Upflow Anaerobic Sludge Blanket Reactor
Published on: October 15, 2015
[Determination of time-weighted average concentration for vinyl chloride in the air of workplace]
Jing Liu1, Li-Xing Zheng, Shang-Jian Chai
1School of Public Health, Fudan University, Shanghai 200032, China.
Objective:
To establish a gas chromatographic method with carbon disulfide desorption for time-weighted average (TWA) concentration of vinyl chloride in the air of workplace.
Methods:
Vinyl chloride in the air was sampled individually with activated charcoal tube. Vinyl chloride was desorbed by carbon disulfide for 30 minutes and analyzed by GC (FID). Time was used for qualitative analysis and peak area was for quantitative analysis.
Results:
Linearity range was 0.0264-1.6896 mmol/L and the coefficient of correlation was 0.9999. Limit of detection: 1.2 ng (injection of 1microl). Relative standard deviation that expressed precision ranged from 3.8% to 6.7% for different concentrations. And average desorption efficiency of carbon disulfide was 90.77%.
Conclusion:
These indicators were corresponding to the Chinese guideline of the method for determination of toxic substances in workplace air and confirmed to be suitable for determining TWA concentration of vinyl chloride in workplace.