Pitfalls in drying oils identification in art objects by gas chromatography
Related Experiment Video
Updated: Aug 6, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Andreas K Tsakalof1, Kyriaki A Bairachtari, Ioannis D Chryssoulakis
1Department of Medicine, University of Thessaly, Larisa, Greece. atsakal@med.uth.gr
Abstract:
Drying oils identification in art objects is an important step in the scientific investigation of the artifact which provides conservators and art historians with valuable information concerning materials used and painting techniques applied. The present communication is devoted to pitfalls and troubleshooting in drying oils identification by means of GC-MS analysis of fatty acids composition in a microsample of an art object. We demonstrate that in the case of nonlinear instrument response the ratios of palmitic to stearic (P/S), distinctive for each oil type and used for drying oil identification, depend on sample dilution so that different dilutions of the same sample can give different P/S ratios. This phenomenon can hinder drying oil identification and lead to erroneous interpretations. This is an important observation as nowadays very often the P/S ratio is calculated from the corresponding peak area ratios or by the use of one-point calibration method. In these approaches, the linearity of the instrument response is not controlled and ensured. In the case analyzed, the nonlinear instrument response was attributed to incomplete sample evaporation in the injector. Packing of the glass liner with deactivated glass wool improved the sample evaporation and ensured the linearity of the instrument response and independence of the P/S ratio from sample dilution.
More Related Videos
08:07A Two-Step Pyrolysis-Gas Chromatography Method with Mass Spectrometric Detection for Identification of Tattoo Ink Ingredients and Counterfeit Products
Published on: May 22, 2019
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...