Point of care ultrasound for basic haemodynamic assessment: novice compared with an expert operator
C F Royse1, J L Seah, L Donelan
1Cardiovascular Therapeutics Unit, Department of Pharmacology, University of Melbourne, Carlton, Victoria, Australia 3010. colin.royse@mh.org.au
Abstract:
Miniaturization of ultrasound equipment has led to the development of hand-held echocardiography devices suitable for bedside evaluation of cardiac function. Basic assessment of the haemodynamic state can be performed using a limited transthoracic echocardiography examination. This study evaluated a third generation device (SonoSite Titan) used by novice and expert operators. Limited transthoracic examination was performed on 30 healthy volunteers by an expert and a novice operator. The novice had performed 10 studies prior to data accrual. Agreement analysis was performed using weighted least products regression and Bland-Altman analysis. Acceptable results for the novice were achieved following 20 studies (including practice sessions) for basic haemodynamic assessment and following 40 studies for all measured parameters. The SonoSite Titan is acceptable for basic transthoracic measurements to determine the basic haemodynamic state and cardiac output measurements. We recommend a minimum of 20 training studies for novice operators prior to clinical use.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.