Present understanding of shock polarity for internal defibrillation: the obvious and non-obvious clinical
Mark W Kroll1, Igor R Efimov, Patrick J Tchou
1California Polytechnic University, St. Louis, Missouri 55323, USA. Mark@krolls.org
Background:
Uncertainty about the best electrode configuration has combined with the programming flexibility in modern implantable cardioverter-defibrillators (ICDs) to result in routine polarity reversal during an implant to deal with a high defibrillation threshold (DFT). We feel that this practice is not always supported by the clinical data and the present scientific understanding of defibrillation.
Method:
A meta-analysis of the clinical studies on ICD shock polarity was performed. Subgroup analyses were also performed to test the impact of high DFTs, various tilts, and the use of the hot can electrode. A review of the basic research surrounding the effects of polarity in defibrillation is also presented.
Results:
A total of 224 patients were studied. The use of an anodal right ventricular (RV) coil lowers the mean DFT by 14.8% (P = 0.00001). It provides thresholds equal to or lower than cathodal defibrillation in 83% of patients. The fraction of patients with lower anodal DFTs was 94/224 versus 38/224 for cathodal polarity. This phenomenon may be explained by virtual electrode effects. In particular, anodal electrodes tend to produce collapsing wavefronts while cathodal electrodes tend to produce expanding proarrhythmic wavefronts.
Conclusion:
In an ICD implant, the RV coil should be the anode. Furthermore, DFT testing beginning with cathodal defibrillation is most likely unnecessary and needlessly extends the procedure's duration and increases the risks for the patient.
Related Concept Videos
Cardiopulmonary Resuscitation III: AED Use
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Cardiopulmonary Resuscitation IV: Pharmacological Management
Potential Due to a Polarized Object