Validated HPLC-MS-MS method for simultaneous determination of atorvastatin and 2-hydroxyatorvastatin in human
V Borek-Dohalský1, J Huclová, B Barrett
1Bioanalytical Laboratory, CEPHA s.r.o. Plzen, Komenskeho 19, 32300 Plzen, Czech Republic. dohalsky@cepha.cz
Abstract:
Cholesterol-reducing statin drugs are the most frequently prescribed agents for reducing morbidity and mortality related to coronary heart disease. In this publication a validated, highly sensitive, and selective isocratic HPLC method is reported for quantitative determination of the major statin drug atorvastatin (ATV) and its metabolite 2-hydroxyatorvastatin (HATV). Detection was performed with an electrospray ionization triple-quadrupole mass spectrometer equipped with an ESI interface operating in positive-ionization mode. Multiple reaction monitoring (MRM) was used for MS-MS detection. The calibration plot was linear in the concentration range 0.10-40.00 ng mL(-1) for both ATV and HATV. Inter-day and intra-day precision and accuracy of the proposed method were characterized by measurement of relative standard deviation (RSD) and percentage deviation, respectively; both were less than 8% for both analytes. The limit of quantitation was 0.02 ng mL(-1) for ATV and 0.07 ng mL(-1) for HATV. The method was used for pharmacokinetic study of ATV and HATV. Pharmacokinetic data for all analytes are also reported.
Related Concept Videos
Measurement of Bioavailability: Pharmacodynamic Methods
Measurement of Bioavailability: Pharmacokinetic Methods
Pharmacokinetics in Geriatric Patients: Effect of Age on Drug Metabolism
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...