Related Experiment Video
Updated: Jul 20, 2026

Sampling and Analysis of Animal Scent Signals
Published on: February 13, 2021
Solid-phase microextraction as a novel air sampling technology for improved, GC-olfactometry-based assessment of
Jacek A Koziel1, Lingshuang Cai, Donald W Wright
1Department of Agricultural and Biosystems Engineering, Iowa State University, Ames, IA, USA.
Abstract:
Air sampling and characterization of odorous livestock gases is one of the most challenging analytical tasks. This is because of low concentrations, physicochemical properties, and problems with sample recoveries for typical odorants. Livestock operations emit a very complex mixture of volatile organic compounds (VOCs) and other gases. Many of these gases are odorous. Relatively little is known about the link between characteristic VOCs/gases and, specifically, about the impact of characteristic odorants downwind from sources. In this research, solid-phase microextraction (SPME) is used for field air sampling of odors downwind from swine and beef cattle operations. Sampling time ranges from 20 min to 1 h. Samples are analyzed using a commercial gas chromatography-mass spectrometry-olfactometry system. Odor profiling efforts are directed at odorant prioritization, with respect to distance from the source. The results indicate the odor downwind is increasingly defined by a smaller number of high-priority odorants. These "character defining" odorants appear to be dominated by compounds of relatively low volatility, high molecular weight, and high polarity. In particular, p-cresol alone appears to carry much of the overall odor impact for swine and beef cattle operations. Of particular interest is the character-defining odor impact of p-cresol as far as 16 km downwind of the nearest beef cattle feedlot. The findings are highly relevant to scientists and engineers working on improved air sampling and analysis protocols and on improved technologies for odor abatement. More research evaluating the use of p-cresol and a few other key odorants as a surrogate for overall odor dispersion modeling is warranted.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Olfaction
The olfactory receptors are embedded in the cilia of the...