Related Experiment Video
Updated: Jul 20, 2026

Surgical Porcine Model of Chronic Myocardial Ischemia Treated by Exosome-laden Collagen Patch and Off-pump Coronary Artery Bypass Graft
Published on: September 15, 2023
Graft-to-coronary-artery shunt during off-pump coronary artery bypass grafting
Hiroshi Iida1, Hideaki Mori, Yoshio Sudo
1Department of Cardiovascular Surgery, Kimitsu Central Hospital, Sakurai Kisarazu, Chiba, Japan. iidahomburg@hotmail.com
Abstract:
We have developed a simple technique for temporary shunt from the saphenous vein graft to the coronary artery during off-pump coronary anastomosis. The ends of a 2-mm diameter tube were inserted into the distal end of the saphenous vein graft in which proximal anastomosis had been established and into the right coronary artery crux. Blood flow sufficient to maintain adequate hemodynamics was obtained through the shunt tube while suturing around the tube. We successfully employed this technique in 5 patients with acute coronary syndrome. We suggest that this technique may represent an addition to the armamentarium for off-pump anastomosis to the right coronary artery.