A three-compartment thermometry model for the improved estimation of changes in body heat content
Ollie Jay1, Louise M Gariépy, Francis D Reardon
1Laboratory of Human Bioenergetics and Environmental Physiology, School of Human Kinetics, Faculty of Health Sciences, University of Ottawa, Ottawa, Ontario, Canada. ojay@uottawa.ca
Abstract:
The aim of this study was to use whole body calorimetry to directly measure the change in body heat content (DeltaH(b)) during steady-state exercise and compare these values with those estimated using thermometry. The thermometry models tested were the traditional two-compartment model of "core" and "shell" temperatures, and a three-compartment model of "core," "muscle," and "shell" temperatures; with individual compartments within each model weighted for their relative influence upon DeltaH(b) by coefficients subject to a nonnegative and a sum-to-one constraint. Fifty-two participants performed 90 min of moderate-intensity exercise (40% of Vo(2 peak)) on a cycle ergometer in the Snellen air calorimeter, at regulated air temperatures of 24 degrees C or 30 degrees C and a relative humidity of either 30% or 60%. The "core" compartment was represented by temperatures measured in the esophagus (T(es)), rectum (T(re)), and aural canal (T(au)), while the "muscle" compartment was represented by regional muscle temperature measured in the vastus lateralis (T(vl)), triceps brachii (T(tb)), and upper trapezius (T(ut)). The "shell" compartment was represented by the weighted mean of 12 skin temperatures (T(sk)). The whole body calorimetry data were used to derive optimally fitting two- and three-compartment thermometry models. The traditional two-compartment model was found to be statistically biased, systematically underestimating DeltaH(b) by 15.5% (SD 31.3) at 24 degrees C and by 35.5% (SD 21.9) at 30 degrees C. The three-compartment model showed no such bias, yielding a more precise estimate of DeltaH(b) as evidenced by a mean estimation error of 1.1% (SD 29.5) at 24 degrees C and 5.4% (SD 30.0) at 30 degrees C with an adjusted R(2) of 0.48 and 0.51, respectively. It is concluded that a major source of error in the estimation of DeltaH(b) using the traditional two-compartment thermometry model is the lack of an expression independently representing the heat storage in muscle during exercise.
More Related Videos
10:23A Computational Modeling Approach to Investigate the Influence of Hyperthermia on the Tumor Microenvironment
Published on: December 1, 2023
04:54Using a Combination of Indirect Calorimetry, Infrared Thermography, and Blood Glucose Levels to Measure Brown Adipose Tissue Thermogenesis in Humans
Published on: June 2, 2023
Related Concept Videos
Three-Compartment Open Model
Body Temperature
Body Temperature
The average body temperature is approximately 37°C (98.6°F) and typically ranges from 36.1–37.2°C (97–99°F), remaining relatively stable...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature and Thermal Equilibrium
The concept of temperature has evolved from the common concepts of hot and cold. The scientific definition of temperature explains more than just our sense of hot and cold. Temperature is operationally defined as the quantity measured with a thermometer. Furthermore, temperature is...
Calorimetry