Related Experiment Video
Updated: Jul 20, 2026

Using Laser Doppler Imaging and Monitoring to Analyze Spinal Cord Microcirculation in Rat
Published on: May 30, 2018
Human skin microcirculation after brachial plexus block evaluated by wavelet transform of the laser Doppler flowmetry
Svein A Landsverk1, Per Kvandal, Trygve Kjelstrup
1Department of Anesthesiology, Ulleval University Hospital, Oslo, Norway. s.a.landsverk@medisin.uio.no
Background:
The skin microcirculation may be evaluated noninvasively by laser Doppler flowmetry and iontophoresis with acetylcholine and sodium nitroprusside. Wavelet transform of the perfusion signal shows periodic oscillations of five characteristic frequencies in the interval 0.0095-1.6 Hz. The aim of the current study was to investigate alterations in skin microcirculation induced by brachial plexus block, with emphasis on the periodic oscillations.
Methods:
Healthy nonsmokers undergoing hand surgery (n = 13) were anesthetized with brachial plexus block, using bupivacaine, lidocaine, and epinephrine. Skin microcirculation was evaluated by laser Doppler flowmetry and iontophoresis with acetylcholine and sodium nitroprusside before and after brachial plexus block. Wavelet transform of the perfusion signal was performed. As a control group, 10 healthy nonsmokers were included.
Results:
In the anesthetized arm, skin perfusion after brachial plexus block increased from 19 (12-30) to 24 (14-39) arbitrary units (P < 0.01). A significant increase was also seen in the contralateral arm from 17 (14-32) to 20 (14-42) arbitrary units (P < 0.01). After brachial plexus block, spectral analysis revealed a significant reduction in relative amplitude of the oscillatory components within the 0.0095- to 0.021- (P < 0.001) and 0.021- to 0.052-Hz (P < 0.001) intervals in the anesthetized arm.
Conclusion:
Alterations in skin microcirculation induced by brachial plexus block can be evaluated by wavelet transform of the laser Doppler flowmetry signal. Brachial plexus block reduces the oscillatory components within the 0.0095- to 0.021- and 0.021- to 0.052-Hz intervals of the perfusion signal. These alterations are related to inhibition of sympathetic activity and a possible impairment of endothelial function.