Related Experiment Video
Updated: Jul 20, 2026

07:52
Evaluating Postural Control and Lower-extremity Muscle Activation in Individuals with Chronic Ankle Instability
Published on: September 18, 2020
The Cumberland ankle instability tool: a report of validity and reliability testing
Claire E Hiller1, Kathryn M Refshauge, Anita C Bundy
1School of Physiotherapy, University of Sydney, Lidcombe, Australia.
Archives of Physical Medicine and Rehabilitation
|August 29, 2006
Summary
The Cumberland Ankle Instability Tool (CAIT) effectively measures functional ankle instability severity. This simple, valid, and reliable scale demonstrates excellent test-retest reliability for clinical use.
Area of Science:
- Orthopedics
- Sports Medicine
- Rehabilitation Science
Background:
- Functional ankle instability is a common condition affecting many individuals.
- Accurate assessment tools are crucial for effective management and treatment planning.
- The Cumberland Ankle Instability Tool (CAIT) is a proposed measure for assessing this condition.
Purpose of the Study:
- To evaluate the validity and reliability of the Cumberland Ankle Instability Tool (CAIT) for measuring functional ankle instability severity.
- To establish the psychometric properties of the CAIT in a general community sample.
Main Methods:
- A cross-sectional study involving 236 volunteer participants.
- Concurrent validity was assessed by comparing CAIT scores with the Lower Extremity Functional Scale (LEFS) and a visual analog scale (VAS).
- Construct validity, internal reliability, discriminant ability, and test-retest reliability were analyzed using Rasch analysis and intraclass correlation coefficients (ICC).
Main Results:
- The CAIT showed significant correlations with LEFS (rho=.50) and VAS (rho=.76), indicating good concurrent validity.
- Internal reliability was acceptable (Cronbach's alpha=.83), and test-retest reliability was excellent (ICC(2,1)=.96).
- The optimal threshold score for identifying functional ankle instability was 27.5, with a sensitivity of 82.9% and specificity of 74.7%.
Conclusions:
- The Cumberland Ankle Instability Tool (CAIT) is a simple, valid, and reliable instrument for assessing the severity of functional ankle instability.
- The CAIT is suitable for use in clinical and research settings for evaluating patients with ankle instability.
Related Concept Videos
Ankle Joint
The ankle is formed by the talocrural joint (crural = leg). It consists of the articulations between the talus bone of the foot and the distal ends of the tibia and fibula of the leg. The superior aspect of the talus bone is square-shaped and has three areas of articulation. The top of the talus articulates with the inferior tibia. This is the portion of the ankle joint that carries the body weight between the leg and foot. The sides of the talus are firmly held in position by the articulations...
Reliability and Validity
Reliability and validity are two important considerations that must be made with any type of data collection. Reliability refers to the ability to consistently produce a given result. In the context of psychological research, this would mean that any instruments or tools used to collect data do so in consistent, reproducible ways.
