Related Experiment Video
Updated: Jul 20, 2026

Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Effect of system variables involved in packed column supercritical fluid chromatography of stavudine taken as model
N Kaul1, H Agrawal, A R Paradkar
1Department of Pharmaceutical Analytical Chemistry, Bharati Vidyapeeth Deemed University, Poona College of Pharmacy, Erandwane, Pune 411038, Maharashtra, India.
Abstract:
A multifactor optimization technique is successfully applied to study the effect of simultaneously varying the system variables on feasibility of stavudine analysis by packed column supercritical fluid chromatography (PC-SFC). The effect of simultaneously varying the pressure, temperature and modifier concentration was studied to optimize the method in order to obtain excellent chromatographic figures of merit. The method is based on isocratic elution using methanol-modified supercritical carbon dioxide as the mobile phase at the flow rate of 3.0 ml/min through a JASCO Finepak SIL-5, ODS [C(18) (5 microm, 25 cm x 4.6 mm, i.d.)] column support using photodiode array detection. The optimal conditions were determined with the aid of the response surface methodology using 3(3) factorial designs. From the response surface graphs optimum regions were selected to be +1, -1, and +1 for temperature (60 degrees C), pressure (20 MPa) and percent modifier concentration (17.81%, v/v), respectively. Linearity dynamic range was found to be in the range of 2.0-150.0 microg/ml with significantly high value of correlation coefficient. The method was validated for precision, robustness and recovery to assess the viability of the established method. The chromatographic limit of detection and quantitation were 0.80 and 1.50 microg/ml respectively. The method has been successfully used to analyze commercial dosage form to assess the chromatographic performance of SFC system which was found to be 99.91%+/-1.62. The present work briefs the thermodynamic applications of PC-SFC with an emphasis on the results of stavudine. The foremost of such applications is the determination of solute diffusion coefficient in supercritical mobile phase by Taylor-Aris peak broadening technique.
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
High-Performance Liquid Chromatography: Elution Process
Principles Of Column Chromatography
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...