The Microscopic Transcanal Approach in Stapes Surgery Revisited
Published on: February 16, 2022
Promontory drilling in stapedectomy: an anatomical study.
Nicholas C Saunders1, Paul A Fagan
1Department of Otology and Skull Base Surgery, St. Vincent's Hospital, Sydney, Australia. nc.saunders@talk21.com
Summary
This study details safe bone removal from the cochlear promontory during stapedectomy. It provides anatomical guidelines for drilling near the oval window to avoid damaging inner ear structures.
Area of Science:
- Otolaryngology
- Surgical Anatomy
- Neurosurgery
Background:
- Anatomical variants like an overhanging facial nerve or promontory can obstruct footplate access during stapedectomy.
- Drilling the cochlear promontory or creating a 'pothole' in the oval window may be necessary but lacks detailed anatomical guidance.
- Limited published data exists on promontory anatomy relevant to these surgical maneuvers.
Purpose of the Study:
- To provide precise anatomical measurements of the bony promontory.
- To establish safe limits for bone removal inferior to the oval window during stapedectomy.
- To guide the creation of a 'pothole' for floating or depressed footplates.
Main Methods:
- Twenty human temporal bones were dissected and analyzed.
- Detailed measurements were taken to assess the thickness of the promontory bone.
- The proximity of the cochlear endosteum, spiral ligament, and stria vascularis to the oval window was quantified.
Main Results:
- The bony promontory is thickest posteriorly, with the endosteum showing minimal lateral projection.
- Bone thickness decreases anteriorly towards the oval window, with the endosteum closely following the bony contour.
- The distance from the stria vascularis/spiral ligament to the oval window inferior margin is <0.2 mm posteriorly and 0.3-0.5 mm at the footplate midpoint.
Conclusions:
- Bone removal inferior to the posterior one-third of the footplate is safe laterally to a 35-degree line from the superoinferior axis.
- For 'pothole' creation in floating/depressed footplates, the midpoint of the inferior oval window margin is recommended.
- The 'pothole' diameter should not exceed 0.3 mm to ensure safety.