Development of an alarm sound database and simulator
Akihiro Takeuchi1, Minoru Hirose, Toshiro Shinbo
1Department of Medical Informatics, School of Allied Health Sciences, Kitasato University, 1-15-1 Kitasato, Sagamihara, Kanagawa 228-8555, Japan. take@kitasato-u.ac.jp
Journal of Clinical Monitoring and Computing
|August 31, 2006
Summary
This study developed an interactive software package for medical alarm sounds, aiding staff in recognizing and sharing issues. The tool helps identify devices and alarm priorities, though accurate identification rates varied.
Area of Science:
- Biomedical Engineering
- Medical Informatics
- Human Factors Engineering
Background:
- Medical device alarms are critical for patient safety but can be confusing.
- Distinguishing between numerous alarm sounds and their priorities is challenging for healthcare professionals.
Purpose of the Study:
- To develop an interactive software package for presenting, recognizing, and sharing information about medical alarm sounds.
- To facilitate communication about alarm sound issues between medical staff and device manufacturers.
Main Methods:
- Recorded 80 alarm sound files from 41 medical devices under variable conditions.
- Developed an alarm sound database (ASDB.xls) and an alarm sound simulator (AlmSS) software package.
- Assessed the ability of 19 clinical engineers to identify 13 alarm sounds and their priorities using the AlmSS.
Main Results:
- The software package integrated a database of 80 alarm sounds and a simulator for interactive use.
- Overall correct identification rate for alarm sounds was 48%, with six sounds recognized by 63-100% of subjects.
- Recognition rate for alarm sound priority was low at 27%.
Conclusions:
- An interactive software package integrating a database and simulator for medical alarm sounds was successfully developed.
- The Alarm Sound Simulator (AlmSS) proved useful for replaying multiple sounds and interactively designing new ones.
- The developed tool can aid in understanding and improving medical alarm sound management.
Related Concept Videos
Operational Amplifiers
The operational amplifier, often referred to as an op-amp, is a multifaceted building block of a circuit. This electronic component functions like a voltage-controlled voltage source and can also be used to create a voltage- or current-controlled current source. The design of an operational amplifier enables it to execute mathematical operations when external components like resistors and capacitors are linked to its terminals. An op-amp has the capacity to sum signals, amplify a signal,...
Hearing
When we hear a sound, our nervous system is detecting sound waves—pressure waves of mechanical energy traveling through a medium. The frequency of the wave is perceived as pitch, while the amplitude is perceived as loudness.
Design Example
The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
Heart Sounds
Heart sounds are generated by the turbulence in blood flow due to the closing of heart valves. These sounds are best perceived slightly away from the valves, where the blood flow disseminates the sound.
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...