Related Experiment Video
Updated: Jul 20, 2026

Detecting SARS-CoV-2 Virus by Reverse Transcription-Loop-Mediated Isothermal Amplification
Published on: September 8, 2023
Detection of severe acute respiratory syndrome coronavirus in stool specimens by commercially available real-time
1Department of Microbiology, Sunnybrook Health Sciences Centre, B121-2075 Bayview Ave., Toronto, Ontario, Canada M4N 3M5. lisa.louie@sunnybrook.ca
Abstract:
Three commercially available real-time reverse transcriptase PCR assays (the Artus RealArt HPA coronavirus LightCycler, the Artus RealArt HPA coronavirus Rotor-Gene, and the EraGen severe acute respiratory syndrome coronavirus POL assay) and three RNA extraction methodologies were evaluated for the detection of severe acute respiratory syndrome coronavirus RNA from 91 stool specimens. The assays' sensitivities were highest (58% to 75%) for specimens obtained 8 to 21 days after symptom onset. The assays were less sensitive when specimens were obtained less than 8 days or more than 21 days after the onset of symptoms. All assays were 100% specific.