Related Experiment Video
Updated: Jul 20, 2026

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Effect of heat sterilization on surface characteristics and microstructure of Mani NRT rotary nickel-titanium
G Alexandrou1, K Chrissafis, L Vasiliadis
1Department of Endodontology, Dental School, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Aim:
To evaluate the effect of repeated dry heat sterilization on surface characteristics and microstructure of Mani nickel-titanium rotary instruments.
Methodology:
Thirty-three new Mani NRT instruments, size 30, taper 0.04 and 25 mm in length were examined. Twenty-seven instruments were divided into three groups for surface characterization by scanning electron microscopy (SEM). In the first group (n = 3), instruments were examined in the 'as-received' condition and after they had been subjected to 11 sterilization cycles. In the second and third subgroups (n = 12), 12 instruments were prepared for cross-section and a further 12 for longitudinal sectional analysis and evaluated in subgroups of three, after 0, 1, 6 and 11 sterilization cycles. The remaining six instruments were analysed with differential scanning calorimetry (DSC), three in the 'as-received' condition and three after being subjected to 11 cycles of sterilization.
Results:
Scanning electron microscopy observations indicated the presence of debris, pitting and deep milling marks in both new and sterilized files. After 11 sterilization cycles, debris remained and surface roughness was increased significantly (P = 0.05). DSC analyses showed that the specimens in the 'as-received' condition and after 11 sterilization cycles were in the austenite phase or a mixture of austenite and R-phase at 37 degrees C.
Conclusions:
The machining defects and structural imperfections of new Mani instruments are indicative of the difficulty in manufacturing nickel-titanium endodontic instruments. DSC measurements suggest that Mani instruments are capable of superelastic behaviour under clinical conditions.
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Temperature
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Key Techniques in Microbiology