Related Experiment Video
Updated: Jul 20, 2026

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
Broad range analysis of endocrine disruptors and pharmaceuticals using gas chromatography and liquid chromatography
Rebecca A Trenholm1, Brett J Vanderford, Janie C Holady
1Water Quality Research and Development Department, Southern Nevada Water Authority, 1350 Richard Bunker Avenue, Henderson, NV 89015, USA. beck.trenholm@snwa.com
Abstract:
Endocrine disrupting compounds (EDCs) and pharmaceuticals and personal care products (PPCPs) have been globally detected in impacted natural waters. The detection of trace quantities of EDCs and PPCPs in the environment is of great concern since some of these compounds have known physiological responses at low concentrations. EDCs can have a wide range of polarities, acidic and basic moieties, and exist in trace quantities, which often requires numerous complex extractions, large sample collection volumes, and multiple instrumental analyses. A comprehensive method has been developed allowing for the analysis of 58 potential EDCs in various water matrices using a single solid-phase extraction (SPE) of a 1L sample with subsequent analyses using both gas chromatography and liquid chromatography, each coupled with tandem mass spectrometry (GC-MS/MS and LC-MS/MS). Instrument detection limits ranged between 0.12-7.5 pg with corresponding method reporting limits of 1-10 ng l(-1) in water. Recoveries for most compounds were between 50% and 112% with good reproducibility (RSD 6-22%).
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II