A cost-effectiveness analysis of the intrapartum fetal pulse oximetry multicentre randomised controlled trial (the
C E East1, M B Gascoigne, C M Doran
1Perinatal Research Centre, The University of Queensland, Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia. ceast@somc.uq.edu.au
Objective:
To report an economic analysis of the Australian intrapartum fetal pulse oximetry (FPO) multicentre randomised controlled trial (the FOREMOST trial), which examined whether adding FPO to conventional cardiotocographic (CTG) monitoring (intervention group) was cost-effective in reducing operative delivery rates for non-reassuring fetal status compared with the use of CTG alone (control group).
Design:
Cost-effectiveness analysis of the FOREMOST trial.
Setting:
Four Australian maternity hospitals, each with more than 4000 births/year.
Population:
Women in labour at > or =36 weeks of gestation, with a non-reassuring CTG.
Methods:
Costs were for treatment-related expenses, incorporating diagnosis-related grouping costs and direct costs (including fetal monitoring). Incremental cost-effectiveness ratio (ICER) and cost-effectiveness plane were calculated, and sensitivity analysis was conducted. The primary outcome was that of the clinical trial: operative delivery for non-reassuring fetal status avoided in the intervention group relative to that in the control group.
Main Outcome Measures:
The ICER.
Results:
The ICER demonstrated a saving of $A813 for each operative birth for non-reassuring fetal status averted by the addition of FPO to CTG monitoring compared with the use of CTG monitoring alone.
Conclusion:
The addition of FPO to CTG monitoring represented a less costly and more effective use of resources to reduce operative delivery rates for non-reassuring fetal status than the use of conventional CTG monitoring alone.
More Related Videos
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: