Related Experiment Video
Updated: Jul 20, 2026

A Reversible, Non-invasive Method for Airway Resistance Measurements and Bronchoalveolar Lavage Fluid Sampling in Mice
Published on: April 13, 2010
Simulated obesity-related changes in lung volume increases airway responsiveness in lean, nonasthmatic subjects
Li-Ying Wang1, Frank J Cerny, Thomas J Kufel
1School and Graduate Institute of Physical Therapy, College of Medicine, National Taiwan University, Taipei 100, Taiwan, ROC. liying@ntu.edu.tw
Study Objective:
To determine if obesity-related changes in lung volume might contribute to airway reactivity, we investigated the effects of simulated mild obesity-related lung volume reductions on airway responsiveness in lean, nonasthmatic subjects.
Participants And Methods:
We simulated the lung volume reductions of class 1 obesity in eight lean, nonasthmatic subjects by externally mass loading the chest wall and abdomen, and shifting blood volume into the lung with lower limb compression (LLC). Airway responsiveness was assessed by measuring FEV(1) before and after methacholine challenge tests (1, 2.5, 5, 10, and 25 mg/mL) with the following: (1) no intervention (control); (2) external chest loading (CL); (3) LLC; and (4) CL and LLC (COMB) on separate days. Lung function was measured before and after CL, LLC, and COMB were applied.
Results:
The application of CL, LLC, and COMB decreased expiratory reserve volume, functional residual capacity, and total lung capacity compared with baseline. FVC and FEV(1) decreased significantly with CL and COMB, while FEV(1)/FVC did not change compared to baseline. The maximal response to the methacholine challenge increased with CL, LLC, and COMB, with a mean maximal fall of FEV(1) of 9%, 11%, and 18%, respectively, compared to a 6% fall with control.
Conclusions:
We conclude that decreases in lung volume increase airway responsiveness and may account for the increased propensity for increased airway responsiveness in the obese.
More Related Videos
08:30Intraperitoneal Glucose Tolerance Test, Measurement of Lung Function, and Fixation of the Lung to Study the Impact of Obesity and Impaired Metabolism on Pulmonary Outcomes
Published on: March 15, 2018
13:10Evaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique
Published on: May 15, 2013
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Chronic Obstructive Pulmonary Disease III: Chronic Bronchitis Features
Asthma III: Clinical Manifestations
Lung Capacity
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...