Gary H Kramer1, Kevin Capello, Barry M Hauck
1Human Monitoring Laboratory, Radiation Surveillance and Health Assessment Division, Radiation Protection Bureau, 775 Brookfield Road, Ottawa, Ontario, K1A 1C1, Canada. gary_h_kramer@hc-sc.gc.ca
Abstract:
Health physicists are usually concerned with small amounts of radioactivity and strive to develop techniques to measure them; however, following a terrorist attack involving radioactive materials the converse might be the case, and exposed persons may be heavily contaminated. The Human Monitoring Laboratory (HML) has field tested its Portable Personnel Portal (P3) monitors using sources up to 1,700 MBq (47 mCi) to determine the alarm distance as a function of activity. The results show that the P3 monitors are highly sensitive, so much so that siting will be a problem for multiple units if multiple alarms are to be avoided. Building materials will shield the monitors allowing units to be placed closer together than in the open where there is no shielding, but windows and doors reduce shielding and complicate the siting of multiple units. In either situation, careful prior thought should be given to siting the monitors and the logistics of crowd control techniques.
Related Concept Videos
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Personal Protective Equipment
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
PPE Use in Healthcare Settings I: Donning
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...