The Nikon C1si combines high spectral resolution, high sensitivity, and high acquisition speed
1Confocal Systems, Nikon Instruments Incorporation, Melville, NY 11747, USA. jlarson@nikon.net
Abstract:
Spectral imaging is a natural extension of the capabilities of confocal microscopes. The first confocal spectral imaging (CSI) instruments were able to acquire spectral data that allowed the emissions of overlapping fluorescent probes to be assigned to data channels representing a spectrum rather than a range of emission wavelengths. This marked a significant improvement over what could be done by channel series with standard confocal microscopes. However the performance of these earlier designs can fall short in one or more of the following areas; sensitivity, spectral resolution and reproducibility, acquisition speed, and unmixing accuracy. Nikon has recently introduced a new CSI instrument, C1si, that overcomes some of the more serious performance deficiencies of earlier designs through unique optical, electronic, and data handling advances. C1si uses a multianode photomultiplier tube (PMT) as the detector and typically acquires spectral data in a single scan. Sensitivity is enhanced over designs diffracting randomly polarized fluorescence by rotating the polarization of all emission photons to the S-plane, the plane for which the diffraction grating is most efficient. Three diffraction gratings are provided supporting wavelength sampling increments of 2.5, 5, and 10 nm. Improvements have been made in the digitization process to increase detection efficiency as well. C1si is calibrated to a high enough standard that it is possible to share and reproduce data between instruments. The algorithm implemented in the EZ-C1 software is able to accurately and repeatedly unmix fluorescent probes with emission peaks separated by as little as 5 nm. It is possible to unmix probes with emission peaks separated by 20 nm with a 10-1 brightness difference. Three probes can be unmixed with emission peaks contained within a 20 nm range. Acquisition is fast enough and the sensitivity is sufficient for C1si to acquire more than 100 frames of spectral time series data without serious photobleaching.
Related Concept Videos
Confocal Fluorescence Microscopy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Three-Dimensional Microscopy in Microbiology
High-Performance Liquid Chromatography: Types of Detectors
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.