Related Experiment Video
Updated: Jul 20, 2026

Optimization of Radiochemical Reactions using Droplet Arrays
Published on: February 12, 2021
A microplate solid scintillation counter as a radioactivity detector for high performance liquid chromatography in
Gerard J Bruin1, Felix Waldmeier, K Olaf Boernsen
1Novartis Pharma AG, Drug Metabolism and Pharmacokinetics, WSJ-103.4.26, CH-4002 Basel, Switzerland. gerard.bruin@novartis.com
Abstract:
Sensitive radioactivity detection following high performance liquid chromatography (HPLC) separation remains a challenge in many drug metabolism studies with radiolabeled compounds. In this work, solid scintillation counting (SSC) after fraction collection into 96-well plates was evaluated as an off-line radioactivity detection method, in comparison with conventional liquid scintillation counting (LSC). The impact of counting time and biological matrix on the quantification of radiolabeled metabolites and parent drug in samples from animal and human absorption, distribution, metabolism and excretion (ADME) studies was investigated. Three different approaches were used to test whether reliable quantification by off-line SSC detection, which requires an approximately constant counting yield during the entire chromatographic run, can be realized: (i) the measurement of radioactivity-spiked biological blank samples without HPLC separation as an extreme case of biological background, (ii) the measurement of radioactivity-spiked HPLC fractions of biological blank samples and (iii) the comparison of radiochromatograms obtained by off-line SSC and LSC of real samples from ADME studies with radiolabeled compounds. Situations in which variations in SSC yield during an HPLC run are likely to lead to significant errors in quantitation were identified and are discussed. However, examples from a number of animal or human ADME studies showed that in the majority of cases off-line SSC provides very similar quantitative data, compared with the reference method of off-line LSC radioactivity detection. Approaches for validation of the off-line SSC approach in critical cases are discussed. The main advantages of off-line SSC, compared with off-line LSC, are lower detection limits and a substantially higher throughput. Several applications of off-line SSC detection in ADME studies are shown.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Types of Detectors-II

