Portal Hypertension01:22

Portal Hypertension

Portal hypertension is an increase in blood pressure within the portal venous system. Normally, this pressure is less than 5 mmHg. It is considered clinically significant when it rises above 10 mmHg. At this threshold, complications from altered blood flow and venous congestion emerge.EtiologyPortal hypertension arises from conditions that impede blood flow through the liver. The most common cause is cirrhosis, in which chronic liver injury leads to fibrotic scarring. This fibrosis narrows or...
Endoscopic Procedures III: Video Capsule Endoscopy01:28

Endoscopic Procedures III: Video Capsule Endoscopy

Capsule endoscopy, or wireless or video capsule endoscopy, is a diagnostic procedure for examining the entire gastrointestinal tract. Patients swallow a capsule about the size of a vitamin tablet. The capsule is equipped with a transmitter, a battery, an LED light source, and a color video camera to capture images throughout the gastrointestinal tract. This procedure is particularly useful for diagnosing conditions such as Crohn's disease, ulcerative colitis, tumors, polyps, ulcers, unexplained...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The use of computed radiography for routine linear accelerator and simulator quality control.

The British journal of radiology·2009
Same author

Design and implementation of an electronic data recording and processing system for physics quality control checks in external beam radiotherapy.

The British journal of radiology·2006
Same author

Dosimetric characteristics of the Elekta Beam Modulator.

Physics in medicine and biology·2005
Same author

Recording accelerator monitor units during electronic portal imaging: application to collimator position verification during IMRT.

Physics in medicine and biology·2001
Same author

Measurement of the response of Gd2O2S:Tb phosphor to 6 MV x-rays.

Physics in medicine and biology·2001
Same author

A method for controlling image acquisition in electronic portal imaging devices.

Physics in medicine and biology·2001

Related Experiment Video

Updated: Jul 20, 2026

Introduction of an Integrated Pathology Image Management, Artificial Intelligence, and Reporting System
05:33

Introduction of an Integrated Pathology Image Management, Artificial Intelligence, and Reporting System

Published on: July 11, 2025

Developments in electronic portal imaging systems.

M C Kirby1, A G Glendinning

  • 1North Western Medical Physics, Radiotherapy Department, Rosemere Cancer Centre, Royal Preston Hospital, Preston, UK.

The British Journal of Radiology
|September 19, 2006
PubMed
Summary

Electronic portal imaging devices (EPIDs) enhance radiotherapy accuracy by verifying patient positioning. This review details EPID technological advancements and their impact on improving treatment precision.

More Related Videos

Hand-held Clinical Photoacoustic Imaging System for Real-time Non-invasive Small Animal Imaging
09:43

Hand-held Clinical Photoacoustic Imaging System for Real-time Non-invasive Small Animal Imaging

Published on: October 16, 2017

A Pipeline for 3D Multimodality Image Integration and Computer-assisted Planning in Epilepsy Surgery
09:41

A Pipeline for 3D Multimodality Image Integration and Computer-assisted Planning in Epilepsy Surgery

Published on: May 20, 2016

Related Experiment Videos

Last Updated: Jul 20, 2026

Introduction of an Integrated Pathology Image Management, Artificial Intelligence, and Reporting System
05:33

Introduction of an Integrated Pathology Image Management, Artificial Intelligence, and Reporting System

Published on: July 11, 2025

Hand-held Clinical Photoacoustic Imaging System for Real-time Non-invasive Small Animal Imaging
09:43

Hand-held Clinical Photoacoustic Imaging System for Real-time Non-invasive Small Animal Imaging

Published on: October 16, 2017

A Pipeline for 3D Multimodality Image Integration and Computer-assisted Planning in Epilepsy Surgery
09:41

A Pipeline for 3D Multimodality Image Integration and Computer-assisted Planning in Epilepsy Surgery

Published on: May 20, 2016

Area of Science:

  • Medical Physics
  • Radiotherapy Technology

Background:

  • Ensuring geometric accuracy in radiotherapy is crucial for effective treatment delivery.
  • Advanced radiotherapy techniques like conformal and intensity-modulated radiotherapy increase the impact of patient positioning errors.
  • Portal imaging is essential for verifying geometric accuracy during treatment.

Purpose of the Study:

  • To review the evolution and technological advancements of electronic portal imaging devices (EPIDs).
  • To assess the impact of EPID development on image quality and clinical applications in radiotherapy.

Main Methods:

  • Review of technological progression in electronic portal imaging devices (EPIDs).
  • Analysis of changes in image quality and commercial systems.
  • Consideration of current clinical usage and future innovations in EPID technology.

Main Results:

  • EPIDs have significantly progressed, improving the verification of geometric accuracy in radiotherapy.
  • Technological evolution has led to enhanced image quality and expanded clinical utility of EPIDs.
  • Ongoing innovations aim for further improvements in EPID systems and image performance.

Conclusions:

  • EPIDs are vital tools for ensuring geometric accuracy in modern radiotherapy.
  • Continuous technological development of EPIDs is essential for enhancing treatment precision and patient safety.
  • Future innovations in EPID technology promise further advancements in radiotherapy delivery.