Related Experiment Video
Updated: Jul 19, 2026

Simultaneous Laryngopharyngeal and Conventional Esophageal pH Monitoring
Published on: December 14, 2020
Multichannel intraluminal impedance for the assessment of post-fundoplication dysphagia
T Yigit1, E Quiroga, B Oelschlager
1The Swallowing Center, Department of Surgery, University of Washington, Seattle, WA, USA.
Abstract:
Dysphagia often occurs after fundoplication, although its pathophysiology is not clear. We sought to better understand postfundoplication dysphagia by measuring esophageal clearance with multichannel intraluminal impedance (MII) along with more traditional work-up (manometry, upper gastrointestinal imaging [UGI], endoscopy). We evaluated 80 consecutive patients after laparoscopic fundoplication between April 2002 and November 2004. Patients were evaluated clinically and underwent simultaneous manometry and MII, 24-hour pH monitoring, endoscopy, and UGI. For analysis, patients were divided into the following groups based on the presence of dysphagia and fundoplication anatomy (by UGI/endoscopy): (1) Dysphagia and normal anatomy; (2) Dysphagia and abnormal anatomy; (3) No dysphagia and abnormal anatomy; and (4) No dysphagia and normal anatomy. Patients with dysphagia (Groups 1 & 2) had similar peristalsis (manometry), but were more likely to have impaired clearance by MII (32 pts, 62%) than those without dysphagia (9 pts, 32%, P = 0.01). Patients with abnormal anatomy (Groups 2 & 3) were also more likely to have impaired esophageal clearance (66%vs. 38%, P = 0.01). Finally, of patients that had normal fundoplication anatomy, those with dysphagia were much more likely to have impaired clearance (12 pts, 52%) than those with dysphagia (4 pts, 21%, P = 0.03). MII after fundoplication provides objective evidence of esophageal clearance, and is commonly abnormal in patients with abnormal fundoplication anatomy and/or dysphagia. Esophageal clearance is impaired in the majority of patients with postoperative dysphagia, even with normal fundoplication anatomy and normal peristalsis. MII may detect disorders in esophageal motility not detected by manometry.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Esophageal Achalasia
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...

