Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
[Intermediate results of aortic valve replacement using 19 mm bioprosthetic valve]
Toshihiro Funatsu1, M Takeuchi, T Masai
1Department of Cardiovascular Surgery, Sakurabashi Watanabe Hospital, Osaka, Japan.
Abstract:
Pre- and postoperative hemodynamic parameters and activity of daily life were reviewed to estimate the effectiveness of the valve in 12 cases of single aortic valve replacement (AVR) using 19 mm bioprosthesis. All implanted prostheses were stented-valves. Carpentier-Edwards pericardial valve was used in 7 cases and Mosaic valve in 5. Left ventricular mass index (LVMI) significantly decreased from 167 +/- 36 to 133 +/- 27 g/m2 in the early postoperative period, and to 115 +/- 24 g/m2 in the intermediate phase. However, postoperative LVMI remained higher in patients with body surface area (BSA) over 1.5 m2 than in those under 1.5 m2. Postoperative activity indicated by New York Heart Association (NYHA) grade significantly improved from 2.3 +/- 1.1 to 1.4 +/- 0.5. These results indicates usefulness of 19 mm bioprosthetic valve for reducing left ventricular hypertrophy and improving activity, especially in patients with BSA smaller than 1.5 m2.