Related Experiment Video
Updated: Jul 19, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Vertebral artery origin stenting with buddy wire technique in tortuous subclavian artery
1Baskent University Department of Radiology, Adana Teaching and Medical Research Center, 01170 Yuregir-Adana, Turkey. ebos90@hotmail.com
Insights
Navigating tortuous vessels during vertebral artery stenting is challenging. A novel buddy wire technique enhances guiding catheter stability, enabling successful stenting in difficult anatomies.
Area of Science:
- Vascular Surgery
- Interventional Neuroradiology
- Cardiovascular Interventions
Background:
- Catheterization of tortuous and atherosclerotic vessels poses significant technical challenges.
- These challenges are linked to an increased risk of vascular complications.
- Specifically, guiding catheter placement in the tortuous subclavian artery for vertebral artery origin stenting is difficult, often resulting in poor backup support.
Purpose of the Study:
- To describe an innovative technique for managing guiding catheter placement in challenging anatomies.
- To facilitate vertebral artery origin stenting in patients with severe aortic arch and subclavian artery tortuosity.
- To improve procedural success and potentially reduce vascular complications in complex neurointerventional cases.
Main Methods:
- A technique utilizing a 'buddy wire' was employed to stabilize the guiding catheter.
- This method was applied during vertebral artery origin stenting procedures.
- The technique addresses difficulties associated with severe tortuosity of the aortic arch and proximal subclavian artery.
Main Results:
- The buddy wire technique successfully stabilized the guiding catheter in the desired position.
- This stabilization enabled the performance of stenting for vertebral artery origin stenosis.
- The described method offers a viable solution for complex cases previously deemed technically challenging.
Conclusions:
- The buddy wire technique is an effective method for improving guiding catheter stability in tortuous vessels.
- This technique facilitates successful vertebral artery origin stenting in challenging anatomies.
- It represents a valuable addition to the interventional neuroradiologist's armamentarium for complex vascular interventions.
Abstract:
Catheterization of vessels with severe tortuosity and atherosclerotic changes may represent a technical challenge and is associated with a higher incidence of vascular complications [Putman CM, Chaloupka JC. Use of large-caliber coronary guiding catheters for neurointerventional applications. AJNR Am J Neuroradiol 1996;17:697-704]. Placement of guiding catheter to the tortuous subclavian artery in vertebral artery origin stenting procedure is such a condition with difficulties. In the presence of severe tortuosity of aortic arch and proximal subclavian artery placement of guiding catheter may be difficult and yield poor backup support. We describe a technique that uses a buddy wire to make the guiding catheter stable in its proper position and make possible to perform stenting the vertebral artery origin stenosis.
