Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
Characterization of typical chemical background interferences in atmospheric pressure ionization liquid
Xinghua Guo1, Andries P Bruins, Thomas R Covey
1Mass Spectrometry Core Facility, University of Groningen, Antonius Deusinglaan 1, 9713 AV Groningen, The Netherlands.
Abstract:
The structures and origins of typical chemical background noise ions in positive atmospheric pressure ionization liquid chromatography/mass spectrometry (API LC/MS) are investigated and summarized in this study. This was done by classifying chemical background ions using precursor and product ion scans on most abundant background ions to draw a family tree of the commonly occurring chemical background ions. The possible structures and the origins of the major chemical background noise are clearly revealed in the family trees. In agreement with some suggestions in the literature, the chemical background ions studied so far can be classified mainly as either ions of contaminants (or their degradation fragments) or cluster-related ones. A significant contribution from the contaminants (airborne, from tubing and/or solvents) from plasticizer additives (phthalates, phenyl phosphates, sebacates and adipates, etc.) and silicones is concluded. These ions of contaminants can also serve as nuclei for the clustering of HPLC solvent or additives, such as water and acetic acid, thereby leading to a second family of background ions. This study explains the persistence of some chemical background noise even under fairly strong declustering conditions in API LC/MS. One of the other interesting conclusions is that there is a clear difference in structures between the chemical background ions and the protonated analytes generated under atmospheric pressure ionization. This conclusion will contribute to the on-going research efforts to exclusively remove or reduce the interference of chemical background noise in API LC/MS.
More Related Videos
05:48Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
Published on: July 11, 2017
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Chemical Ionization (CI) Mass Spectrometry
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
High-Performance Liquid Chromatography: Types of Detectors
Atomic Emission Spectroscopy: Interference