Related Experiment Video
Updated: Jul 19, 2026

Correction of Presbyopia by Monocular Bi-Aspheric Ablation Profile
Published on: September 20, 2024
Optical quality of the cornea after overnight orthokeratology
Takahiro Hiraoka1, Fumiki Okamoto, Yuichi Kaji
1Department of Ophthalmology, Institute of Clinical Medicine, University of Tsukuba, 1-1-1 Tennoudai, Tsukuba, Ibaraki 305-8575, Japan. thiraoka@md.tsukuba.ac.jp
Purpose:
To review changes in the optical quality of the cornea induced by overnight orthokeratology for myopia.
Methods:
Sixty-four eyes of 39 patients who underwent overnight orthokeratology for myopia were prospectively examined. Inclusion criteria were uncorrected visual acuity of 20/20 or better after treatment and a minimum follow-up of 3 months. To quantitatively assess changes in corneal regular and irregular astigmatism, videokeratography data were decomposed into spherical component, regular astigmatism, asymmetry, and higher-order irregularity using Fourier analysis. In addition, corneal wavefront aberrations were calculated by expanding anterior corneal height data from videokeratography into a set of orthogonal Zernike polynomials.
Results:
Although orthokeratology significantly reduced manifest refraction and improved uncorrected visual acuity, the asymmetry component, which is one of the features of irregular astigmatism, increased significantly from 0.35 +/- 0.22 to 0.64 +/- 0.40 D after treatment (P < 0.0001, paired t test). The increases in the asymmetry component significantly correlated with the amount of myopic correction (Pearson correlation coefficient, R = 0.40, P = 0.0009). Furthermore, the root-mean-square of third-order (coma-like) and fourth-order (spherical-like) aberrations significantly increased after orthokeratology (P < 0.0001, paired t test), and these increases showed significant positive correlations with the amount of myopic correction (Pearson correlation coefficient, R = 0.452, P = 0.0001 and R = 0.381, P = 0.0017, respectively).
Conclusion:
Corneal irregular astigmatism and higher-order aberrations significantly increased even in clinically successful orthokeratology, and the increases correlated with the magnitude of myopic correction. A large myopic correction by orthokeratology should be avoided to not decrease corneal optical quality.