Related Experiment Video
Updated: Jul 19, 2026

High-definition Fourier Transform Infrared (FT-IR) Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
Published on: January 21, 2015
Cell discrimination by attenuated total reflection-Fourier transform infrared spectroscopy: the impact of
A Gaigneaux1, J M Ruysschaert, E Goormaghtigh
1Laboratory for the Structure and Function of Biological Membranes, Center for Structural Biology and Bioinformatics, CP 206/2, Free University of Brussels (ULB), Bld du triomphe, Acces 2, B-1050 Brussels, Belgium.
Abstract:
Fourier transform infrared (FT-IR) spectroscopy has become a powerful tool for biodiagnostics and cell line classification. Typical experimental perturbations included in spectra are baseline shift and scale variation between spectra. They have to be removed by data preprocessings to allow further data analysis and classification. In this work, we addressed baseline shift corrections and normalizations in attenuated total reflection (ATR) FT-IR spectra. We compared the efficiency of several preprocessing methods with series of spectra containing typical perturbations (baseline shift, scaling factor, and noise) and a priori known definite spectral difference. Several baseline-correction and normalization possibilities were evaluated. Our results were generally sensitive, selective, and robust with respect to baseline and scaling. Full-range scaling generated more false-positive results. Use of first- and second-derivative spectra was tested. Results obtained on model spectra were confirmed with series of spectra from sensitive and multidrug-resistant leukemia K562 cells. We showed that the use of derived spectra did not provide more efficiency and required additional preprocessing such as smoothing to obtain results similar to those obtained from non-derived ones. On the other hand, results obtained with derivatives were less sensitive to scaling, a useful feature when scaling is problematic.
More Related Videos
10:50Detection and Quantification of Plasmodium falciparum in Aqueous Red Blood Cells by Attenuated Total Reflection Infrared Spectroscopy and Multivariate Data Analysis
Published on: November 2, 2018
08:57Improving Infrared Spectroscopy Characterization of Soil Organic Matter with Spectral Subtractions
Published on: January 10, 2019
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
IR Spectrometers
IR Frequency Region: Fingerprint Region
The...
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Applications of IR Spectroscopy: Overview