Improving Infrared Spectroscopy Characterization of Soil Organic Matter with Spectral Subtractions
Published on: January 10, 2019
Removal of analyte-irrelevant variations in near-infrared tissue spectra
Ye Yang1, Leah Shoer, Olusola O Soyemi
1Department of Anesthesiology, University of Massachusetts Medical School, 55 Lake Avenue North, Worcester, Massachusetts 01655, USA. ye.yang@umassmed.edu
Abstract:
This paper describes mathematical techniques to correct for analyte-irrelevant optical variability in tissue spectra by combining multiple preprocessing techniques to address variability in spectral properties of tissue overlying and within the muscle. A mathematical preprocessing method called principal component analysis (PCA) loading correction is discussed for removal of inter-subject, analyte-irrelevant variations in muscle scattering from continuous-wave diffuse reflectance near-infrared (NIR) spectra. The correction is completed by orthogonalizing spectra to a set of loading vectors of the principal components obtained from principal component analysis of spectra with the same analyte value, across different subjects in the calibration set. Once the loading vectors are obtained, no knowledge of analyte values is required for future spectral correction. The method was tested on tissue-like, three-layer phantoms using partial least squares (PLS) regression to predict the absorber concentration in the phantom muscle layer from the NIR spectra. Two other mathematical methods, short-distance correction to remove spectral interference from skin and fat layers and standard normal variate scaling, were also applied and/or combined with the proposed method prior to the PLS analysis. Each of the preprocessing methods improved model prediction and/or reduced model complexity. The combination of the three preprocessing methods provided the most accurate prediction results. We also performed a preliminary validation on in vivo human tissue spectra.
More Related Videos
Related Concept Videos
IR Frequency Region: Fingerprint Region
The...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...