Contamination and decontamination of Doppler probes
Emma J Whitehead1, John F Thompson, David R Lewis
1Department of Surgery, Royal Devon and Exeter Hospital, Exeter, UK. Emma.Whitehead@phnt.swest.nhs.uk
Introduction:
Nosocomial infection occurs in 2-9% of patients undergoing vascular surgery and can lead to death, amputation or require complex revision surgery. Neck ties, pagers, stethoscopes and Doppler probes have been shown to carry pathogens. We measured bacterial colonisation of Doppler probes on a vascular unit and audited the effect of staff education at reducing this contamination.
Materials And Methods:
Bacteriological culture swabs were taken from hand-held Doppler probes on the vascular surgical ward and clinic. There was no protocol for cleaning the Doppler probes, so manufacturers were contacted for their recommendations. The results of cultures were presented to nursing and medical staff, who were then asked to clean the probes with alcohol wipes after each use. After an interval of 1 week, bacteriological cultures from the same Doppler probes was repeated.
Results:
Fifty bacteriological cultures were performed from 10 Doppler probes over a 4-week period. Thirteen (26%) cultures were positive for diphtheroids, coliforms, coagulase-negative staphylococci and skin flora. After staff education, 42 further swabs were taken from the same probes; two positive cultures were obtained with scanty growth of skin flora (chi2 P < 0.05).
Conclusions:
Staff education and simple cleaning significantly reduces the contamination of hand-held Doppler probes and may help prevent nosocomial infection.
More Related Videos
10:15The Use of the Ex Vivo Chandler Loop Apparatus to Assess the Biocompatibility of Modified Polymeric Blood Conduits
Published on: August 20, 2014
09:56Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
Published on: November 4, 2014
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Doppler Effect - II
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...