Related Experiment Video
Updated: Jul 19, 2026

A Customizable Approach for the Enzymatic Production and Purification of Diterpenoid Natural Products
Published on: October 4, 2019
Influence of different purification techniques on triamcinolone yield and particle size spectrum
Peter Szurman1, Radoslaw Kaczmarek, Gesine B Jaissle
1Department of Ophthalmology I, University of Tuebingen, Schleichstr. 12, 72076, Tuebingen, Germany. Peter.Szurman@med.uni-tuebingen.de
Background:
To systematically investigate the common purification techniques for commercially available triamcinolone acetonide preparations and the influence of different filter parameters on final yield, reproducibility and particle size spectrum.
Methods:
Two non-filter techniques using either sedimentation or centrifugation, and two different filter techniques were tested. Filters with different characteristics were investigated with the pore size ranging from 0.1 to 5.0 microm, and the filter diameter ranging from 4 to 30 mm. Only sterile standard syringe filters with low adsorptive characteristics (hydrophilic cellulose filter membranes) for pharmaceutical use were employed. For quantification, triamcinolone acetonide was dissolved in 60% methanol and measured spectrophotometrically at 239 nm. The crystal size spectrum was determined using a particle size analyzer that combines electronic pulse area analysis and resistance measurement.
Results:
Depending on the purification technique used the resulting triamcinolone doses differed significantly. While the centrifugation method achieved purification without relevant loss, the sedimentation method yielded only 28.7% compared to the original commercial suspension, and in addition, the predictability was low (range 8.1-17.2 mg). With filter techniques high and consistent doses with a good reproducibility were achieved, but results were highly dependent on the filter characteristics. The final triamcinolone amount inversely correlated with the filter diameter due to a uniform loss of crystalline particles. In contrast, enlarging the pore size caused a substantial shift in the particle size spectrum due to a selective loss of small crystalline particles.
Conclusions:
The most common purification techniques vary notably in regard to final triamcinolone doses, reproducibility and particle size spectrum. The appropriate choice of the filter parameters seems to be more important than assumed, as pore size and filter diameter substantially influence both the final TA doses and the particle size of the TA crystals.
More Related Videos
08:56Transient Expression in Nicotiana Benthamiana Leaves for Triterpene Production at a Preparative Scale
Published on: August 16, 2018
10:33Development of Inhibitors of Protein-protein Interactions through REPLACE: Application to the Design and Development Non-ATP Competitive CDK Inhibitors
Published on: October 26, 2015
Related Concept Videos
Factors Affecting Dissolution: Particle Size and Effective Surface Area
Pharmaceutical Alternatives: Polymorphic Form-Related and Particle Size-Related Therapeutic Nonequivalence