Related Experiment Video
Updated: Jul 19, 2026

Electrochemical Preparation of Poly(3,4-Ethylenedioxythiophene) Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Metal/polypyrrole quasi-reference electrode for voltammetry in nonaqueous and aqueous solutions
Jalal Ghilane1, Philippe Hapiot, Allen J Bard
1Department of Chemistry and Biochemistry, University of Texas at Austin, Austin, Texas 78712, USA.
Abstract:
As an alternative to the usual commercial reference and quasi-reference electrodes (QREs), we propose metal (Pt, stainless steel) coated with partially oxidized polypyrrole as a QRE. The electrode is easily fabricated by cyclic voltammetry (CV) with the metal electrode in an acetonitrile or CH2Cl2 solution of 10 mM pyrrole containing 0.1 M Bu4NPF6. These QREs were more stable than the widely used metal (e.g., Ag, Pt) wire QRE as demonstrated by testing in several aqueous and organic media, with the stability checked by CV with ferrocenemethanol as the redox species. The results obtained demonstrate good stability of these QREs over a period of 1 day and relatively reproducible potential in a given solvent and supporting electrolyte. This electrode has the advantage that it does not contaminate the test solution with ions or solvent from a usual liquid electrolyte (e.g., the KCl in an Ag/AgCl). It is also simple to fabricate very small electrodes for use in nanocells, e.g., in scanning tunneling and electrochemical microscopy.
More Related Videos
09:18Simple Methods for the Preparation of Non-noble Metal Bulk-electrodes for Electrocatalytic Applications
Published on: June 21, 2017
09:17Reductive Electropolymerization of a Vinyl-containing Poly-pyridyl Complex on Glassy Carbon and Fluorine-doped Tin Oxide Electrodes
Published on: January 30, 2015
Related Concept Videos
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetric Techniques: Pulse Voltammetry
Voltammetric Techniques: Cyclic Voltammetry
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...