Related Experiment Video
Updated: Jul 19, 2026

Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Multidetector CT (64 Slices) of the liver: examination techniques
1Department of Radiological Sciences, University of Rome "La Sapienza", Polo Pontino-ICOT, Latina, Italy. andrea.laghi@uniroma1.it
Abstract:
Sixty-four-row MDCT, although developed primarily for cardiac imaging, has the potential to have a great impact on liver imaging as well. Liver-imaging protocols with sub-millimeter collimation improve longitudinal spatial resolution, making the acquired dataset a real isotropic volume perfectly designed for optimal three-dimensional rendering and accurate organ and lesion volumetry. The 64-row detector array offers a wide volumetric coverage (up to 40 mm), suitable not only for shortening scanning time and improving spatial resolution, but also for including a large volume per single rotation, particularly useful for accurate CT perfusion studies. In order to take full benefit from the enormous performance offered by new 64-row MDCT scanners, imaging protocols need to be redesigned. Due to the extremely short scanning window, contrast agent injection should be performed at high flow rate and followed by saline bolus chaser; the use of highly concentrated contrast media might be useful. Timing should be accurately calculated either by a test bolus or, better, by using an automatic bolus-detection technique. Radiation exposure is kept under control, using automatic device-modulating dose delivery according to the patient's anatomy. Finally, the evaluation of acquired volumetric datasets needs the extensive use of a dedicated workstation, with software with sophisticated rendering capabilities.
More Related Videos
12:39DUCT: Double Resin Casting followed by Micro-Computed Tomography for 3D Liver Analysis
Published on: September 28, 2021
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET