Adsorption isotherm of CO on Pt(111) electrodes

Angel Cuesta1, María del Carmen Pérez, Alejandro Rincón

  • 1Instituto de Química Física Rocasolano, CSIC, C. Serrano, 119, E-28006 Madrid, Spain. a.cuesta@iqfr.csic.es

Related Concept Videos

Potentiometry: Types of Electrodes01:19

Potentiometry: Types of Electrodes

Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Adsorption Isotherms I01:29

Adsorption Isotherms I

Adsorption isotherms are mathematical models that describe how molecules in a gas or liquid phase interact with surfaces. Two of the most common isotherm models are the Langmuir and Freundlich isotherms, which relate to Type I monolayer chemisorption. The Langmuir model is based on four key assumptions:• Adsorption cannot exceed monolayer coverage.• All surface sites are equivalent.• Molecules adsorb only at vacant sites.• There are no interactions between adsorbed molecules.Consider the...
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential ensures...
Adsorption Isotherms II01:25

Adsorption Isotherms II

Brunauer, Emmett, and Teller (BET) introduced a theory in 1938 that modified Langmuir's assumptions to explain multilayer physical adsorption. This theory is applicable to Type II isotherms and provides a more realistic picture of adsorption processes. The BET theory assumes a uniform solid surface with localized adsorption sites, where adsorption at one site doesn't affect adsorption at neighboring sites. This theory also allows for the possibility of additional molecules being adsorbed on top...
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
Types of Reversible Electrodes01:24

Types of Reversible Electrodes

For electrode reversibility to be maintained, all the reactants and products involved in the half-reaction must be present at the electrode. There are several types of reversible electrodes (half-cells).In metal-metal-ion electrodes, a metal balances electrochemically with a solution of its own ions. Examples are Cu2+|Cu and Zn2+|Zn. Metals that react with the solvent, like group 1 and most group 2 metals, which react with water, and zinc, which reacts with aqueous acidic solutions, cannot be...