Related Experiment Video
Updated: Jul 19, 2026

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Preferred collagen fiber orientation human peri-implant bone after a short- and long-term loading period: a case
Tonino Traini1, Gabriele Pecora, Giovanna Iezzi
1Dental School, University of Chieti-Pescara, Italy.
Abstract:
Immediate loading of dental implants offers treatment cost advantages to patients and avoids the functional and psychological problems caused by the wearing of provisional dentures. There is evidence that the amount of transverse collagen fiber orientation in bone is influenced by mechanical stresses and strains. Two osseointegrated dental implants in humans were used in the present study. Two implants inserted in the maxilla were analyzed: 1 short-term implant (implant A) immediately loaded and retrieved after 4 months of loading and 1 long-term implant (implant B) immediately loaded and retrieved after 12 years. We hypothesized that the bone functional strain caused by immediate loading correlated well with the collagen fiber organization occurring after both short- and long-term functional healing. Circularly polarized light (CPL) was used to assess the area fraction extension related to the transverse collagen fiber orientation in the bone matrix. After evaluating a total of 68 digitized images taken at x50 magnification, birefringence measurements were performed all around the implant surfaces by using 2 central sections from each implant. The results showed that the bone-to-implant contact (BIC) percentage for implant A was 67.9% +/- 9.5% (mean +/- SD), whereas the BIC percentage for implant B was 74.6% +/- 11.2% (mean +/- SD). The area fraction extension was 2.7% +/- 1.4 % (mean +/- SD) for implant A, whereas the area fraction extension was 4.7% +/- 1.2% (mean +/- SD) for implant B. The CPL measurements of the birefringence for transverse collagen fibers of implant A vs implant B indicated that the bone fraction area difference was not high. In the bone near both dental implants, no differences were found in the amount of transverse collagen fibers. Immediate loading seemed to determine and maintain the collagen fiber's orientation over a long period.
More Related Videos
Related Concept Videos
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
Normal Strain under Axial Loading

