Characterization of linear and cyclic polylactic acids and their solvolysis products by electrospray ionization mass
Issey Osaka1, Mikio Watanabe, Masashi Takama
1Department of Applied Chemistry, Kansai University, Yamatecho, Suita 564-8680, Japan.
Abstract:
Linear and cyclic polylactic acids (PLAs) were characterized using electrospray ionization mass spectrometry (ESI-MS) as part of our ongoing investigation of the hydrolysis mechanism of biodegradable polymers. The condensation oligomers of linear polylactic acid (LPLA) were synthesized by thermal dehydration of L-lactic acid. The trimer and tetramer base polymers of cyclic polylactic acid (CPLA) were obtained by cyclization reactions of lactic acid trimers and tetramers, respectively. In the ESI-MS/MS measurement, LPLA yielded three types of product ion series, while CPLA yielded only one type, from which the repeated units of CPLA were removed. The MS/MS spectrum of the NH4+ adduct ion for both cyclic and linear PLA showed loss of one ammonia molecule. The postsource decay (PSD) spectrum of CPLA by matrix-assisted laser desorption ionization (MALDI) mass spectrometry was similar to the ESI-MS/MS spectrum, while that of LPLA was different. In addition, the degradation of cyclic and linear PLAs by solvolysis was investigated. Solvolysis with anhydrous MeOH was quite feasible, but did not readily occur in the presence of even a small amount of water in the MeOH solvent.
Related Concept Videos
Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation
For example, the fragmentation of...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Cycloalkane Fragmentation
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...
Matrix-Assisted Laser Desorption Ionization (MALDI)
MALDI-TOF Mass Spectrometry
Mass Spectrometry: Cycloalkene Fragmentation