Related Experiment Video
Updated: Jun 26, 2026

MRI and PET in Mouse Models of Myocardial Infarction
Published on: December 19, 2013
Diagnosis of misery perfusion using noninvasive 15O-gas PET
Masato Kobayashi1, Hidehiko Okazawa, Tatsuro Tsuchida
1Biomedical Imaging Research Center, University of Fukui, Fukui, Japan.
Unlabelled:
To avoid arterial blood sampling and complicated analyses in 15O-gas PET studies, we evaluated a noninvasive technique using the count-based method for measuring asymmetric increases in oxygen extraction fraction (OEF) in cerebrovascular disease.
Methods:
Eighteen patients (mean age +/- SD, 61 +/- 16 y) with atherothrombotic large-cerebral-artery disease were studied for the measurement of hemodynamic parameters using the 15O-gas steady-state method with inhalation of 15O2, C15O2, and C15O. All patients also underwent H2(15)O PET with the bolus injection method. Count-based ratio images of 15O2/C15O2 and (15)O2/H2(15)O were calculated, and asymmetry indices (AIs) were obtained (cbOEF(SS)-AI and cbOEF(BO)-AI, respectively) using regions of interest drawn bilaterally on the cerebral cortices. These AIs were compared with the AIs of absolute OEF (qOEF-AI) and with those after cerebral blood volume (CBV) correction. A contribution factor for this correction was defined as a variable alpha, and the effect of the correction was evaluated.
Results:
cbOEF(SS)-AI underestimated qOEF-AI significantly, especially with a greater AI (P < 0.05). cbOEF(BO)-AI linearly correlated well with qOEF-AI. CBV correction improved the slopes of regression lines between qOEF-AI and cbOEF(SS)-AI, and the optimal alpha was defined as 0.5. On the other hand, cbOEF(BO)-AI fairly estimated qOEF-AI without CBV correction. Correlation between qOEF-AI and cbOEF(BO)-AI was adversely affected, and the mean bias was increased, with a greater alpha.
Conclusion:
cbOEF(BO)-AI can fairly estimate the AI of OEF without CBV correction, whereas cbOEF(SS)-AI might require CBV correction for better estimation. The examination time and stress to patients would be reduced with the count-based method because it is noninvasive.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET