Assessment of Neuromuscular Function Using Percutaneous Electrical Nerve Stimulation
Published on: September 13, 2015
Neuromuscular monitoring
1Department of Anaesthesia and Intensive Care, Copenhagen University Hospital, Copenhagen, Denmark. viby@rh.dk
Current Opinion in Anaesthesiology
|October 5, 2006
Summary
Anesthetists should prioritize monitoring neuromuscular function using objective methods to prevent postoperative residual curarization. This review covers advanced techniques for assessing neuromuscular blockade during anesthesia.
Area of Science:
- Anesthesiology
- Neuromuscular Physiology
Background:
- Neuromuscular monitoring is crucial during anesthesia.
- Residual neuromuscular block can lead to postoperative complications.
Purpose of the Study:
- To review current techniques for monitoring neuromuscular function during anesthesia.
- To highlight the importance of objective monitoring for preventing residual curarization.
Main Methods:
- Review of recent literature on neuromuscular monitoring techniques.
- Discussion of acceleromyography, surface electromyography, and acoustic myography.
- Evaluation of methods for intense neuromuscular block and residual curarization.
Main Results:
- Acceleromyography is effective for facial and hand muscle monitoring.
- Laryngeal, diaphragmatic surface electromyography, and acoustic myography offer alternative monitoring methods.
- Objective monitoring is essential for managing intense neuromuscular blocks and preventing residual curarization.
Conclusions:
- Current evidence supports increased attention to residual curarization.
- Objective methods for neuromuscular function monitoring should be routinely employed by anesthetists.
- Proper monitoring can significantly reduce postoperative residual neuromuscular blockade.
Related Concept Videos
Pulse rhythm
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Holter Monitor: 24-Hour Monitoring
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
Neuromuscular Junction And Blockade
The site of chemical communication between a motor neuron and a muscle fiber is called the neuromuscular junction (NMJ). The end of the motor neuron at the NMJ divides into a cluster of synaptic end bulbs. The cytoplasm of these bulbs consists of synaptic vesicles enclosing acetylcholine molecules, the principal neurotransmitter released at the NMJ. The region opposite the synaptic bulb that ends in the muscle fiber is called the motor end plate, which has acetylcholine receptors. Within the...