Unexpected higher-order effects in charged particle impact ionization at high energies

M Foster1, J L Peacher, M Schulz

  • 1Physics Department and Laboratory for Atomic, Molecular, and Optical Research, University of Missouri-Rolla, 1870 Miner Circle, Rolla, Missouri 65409, USA.

Physical Review Letters
|October 10, 2006
PubMed

Related Concept Videos

Ionization Energy03:12

Ionization Energy

The amount of energy required to remove the most loosely bound electron from a gaseous atom in its ground state is called its first ionization energy (IE1). The first ionization energy for an element, X, is the energy required to form a cation with 1+ charge:
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
The Energies of Atomic Orbitals03:21

The Energies of Atomic Orbitals

In an atom, the negatively charged electrons are attracted to the positively charged nucleus. In a multielectron atom, electron-electron repulsions are also observed. The attractive and repulsive forces are dependent on the distance between the particles, as well as the sign and magnitude of the charges on the individual particles. When the charges on the particles are opposite, they attract each other. If both particles have the same charge, they repel each other.
Nuclear Overhauser Enhancement (NOE)01:06

Nuclear Overhauser Enhancement (NOE)

Irradiation of a spin-active nucleus causes an increase or decrease in the signal intensity of neighboring nuclei that are not necessarily chemically bonded or involved in J-coupling. This phenomenon, called the nuclear Overhauser enhancement (NOE), results from through-space interactions between the nuclear spins. The NOE effect decreases with increasing internuclear distance and is generally not observed beyond 4 angstroms. In NOE, dipole-dipole interactions between neighboring spin-active...