Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Shrinkage stress in light-cured composite resins: influence of material and photoactivation mode
Christophe Charton1, Pierre Colon, Fernand Pla
1Laboratoire des Sciences du Génie Chimique, UPR 6811, INPL, ENSIC, 1, rue Grandville, BP 451 F-54.001 Nancy Cedex, France. charton.christophe@wanadoo.fr
Objectives:
The aim of this study was to record the effect of composite type and photoactivation mode on the stresses resulting from polymerization of five established composite resins: packable (Solitaire, Solitaire 2), micro-hybrid (Aelitefil, Z100) and hybrid (Clearfil AP-X).
Methods:
A mechanical testing machine was used to record the polymerization contraction stress (MPa) of cylindrical composite specimens (d=5mm; h=2mm; C-factor=1.25) at 0.1s intervals over a period of 400s. The samples were photopolymerized using a halogen light curing device under two types of light exposure: group 1, Standard (800mW.cm(-2)x60s); group 2, Exponential (logarithmic increase from 150 to 800mW.cm(-2) over 15s+800mW.cm(-2)x45s). The stress rate (SR: slope(MPa>0-60s)) and the maximum shrinkage stress (MSS: MPa(400s)) of each material (five replications) were statistically analysed by one-way ANOVA/Scheffe's test and Pearson's correlation procedure (alpha=0.05). Finally, Student's t-test (two matched series) enabled the assessment of the effect of the irradiation method on the results.
Results:
For group 1, in decreasing order, the MSS was 1.51+/-0.07MPa (Solitaire) statistically equivalent to 1.45+/-0.06MPa (Aelitefil), 1.29+/-0.08MPa (Solitaire 2), and 1.04+/-0.03MPa (Z100) statistically equivalent to 0.92+/-0.05MPa (Clearfil AP-X). Z100 showed the highest SR (0.045+/-6x10(-3)) and Solitaire, the lowest (0.017+/-2x10(-3)). There was no correlation between SR and MSS (r<-0.33, p<0.05). For group 2, the MSS and SR values were distributed in a similar way to those from group 1. There was a negative correlation between SR and MSS (r<-0.43 and p<0.01). The exponential ramp successfully reduced the MSS (-3.9%) and SR (-11%) values.
Significance:
There is no relationship between composite resin type, stress rate and shrinkage stress levels. The slower stress rate development, resulting from ramped light intensity, helped slightly to reduce the maximum polymerization stress.
Related Concept Videos
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Accelerated Curing of Concrete
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Carbonation Shrinkage
The concrete's permeability is slightly reduced as calcium carbonate produced during the reaction fills its pores. Furthermore, its strength is slightly enhanced as the water released during the reaction facilitates the...