What difference might sewage treatment performance make to endocrine disruption in rivers?
Andrew C Johnson1, Richard J Williams, Pete Simpson
1Centre for Ecology and Hydrology, Maclean Building, Benson Lane, Crowmarsh Gifford, Wallingford, Oxfordshire, OX10 8BB, UK. ajo@ceh.ac.uk
Abstract:
An assessment of the steroid estrogen removing performance of 23 different sewage treatment plants (STPs) was performed. The assessment relied on a model to estimate influent concentrations, and completed questionnaires on the STP treatment details from the relevant water companies. This information was compared with observed effluent 17beta-estradiol (E2) and estrone (E1) concentrations. The 10 biological filter plants (BFP) in the study performed poorly with only 30% (SD 31) removal on average for E1. This reduced E1 removal performance of the BFPs compared to all the other STP types in the survey was statistically significant (p<0.001). Scenarios of all the STPs as activated sludge types, and one as all BFP types were modelled using the GREAT-ER model set up for the Aire/Calder catchment in the UK. This difference was shown to have an important effect on predicted river E1 concentrations and consequent risk classifications.