Objectives:
To evaluate the safety of an ozone gas device designed for use in dentistry.
Methods:
Two commercially available ozone applicators, Ozi-cure and HealOzone were used in a clinical simulation using a phantom head while recordings of ozone levels were made in pharyngeal and nasal regions of the patient and near the mouth of the operator. Clinical simulations included ozone application for caries management and endodontic treatment. Recordings were made five times with different levels of suction to assess the effect on ozone levels.
Results:
The results with Ozi-cure on caries mode resulted in a peak ozone level in the pharynx of 1.33+/-0.52 ppm when no suction was used. The use of suction nearby reduced the ozone level to zero while suction on the opposite side of the mouth reduced the level to 0.22+/-0.04 ppm. Used on endodontic mode the peak ozone level in the pharynx was 5.51+/-1.63 ppm when no suction was used. The use of suction nearby reduced the ozone level to zero while suction on the opposite side of the mouth reduced the level to 0.84+/-0.54 ppm. Recordings in the patient's nasal region gave a peak of 0.22 ppm when using the Ozi-cure on endodontic mode with no suction. At the operator's mouth the ozone level did not exceed 0.01 ppm although the characteristic smell of ozone was detectable. All recordings with HealOzone were zero. Concentrations of 15 ppm were recorded in a simulated tooth cavity with Ozi-cure and >20 ppm with HealOzone.
Conclusions:
The Ozi-cure device when used without adequate suction allows ozone to be reach a concentration above permitted levels and therefore should not be used. The HealOzone was safe to use.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: